ISTA 1A Package Screening Test
The entry point to the ISTA series. A screening test that challenges packaging strength, quick to run and cheap to fail, and honest about what it does not prove.
- The Cheapest Way to Fail Early: Find the obvious weakness before you spend on a full simulation programme.
- Fast and Repeatable: A single specimen, a short sequence, and a result you can act on quickly.
- Honest About Its Limits: Screening is not simulation. We will tell you when you need more.
- On Our Accredited Scope: The ISTA 1 Series sits on our A2LA ISO 17025 scope, so the report is accredited data.
Accredited package testing

ISO/IEC 17025
A2LA #5179.01

ISTA certified
Certified test laboratory
*Tell us the packed weight and dimensions, and what the report is for. If screening is not enough for your situation we will say so before you book it.
What is ISTA 1A?
ISTA 1A is a non-simulation integrity performance test for individually packaged products up to a set weight ceiling. It challenges the strength of a packaging system with vibration and shock, and reports whether it held.
The word to notice is non-simulation. 1A does not attempt to reproduce a distribution environment, and the standard is explicit about that. It is a strength test, not a prediction of what will happen in a courier network. That sounds like a limitation and it is also the point: a screening test is fast, cheap and repeatable, which makes it the right tool for finding a weakness early rather than for certifying a design at the end.
The ISTA 1 Series is on Megalab’s A2LA ISO/IEC 17025 scope, and we are an ISTA certified laboratory audited by ISTA.
When 1A is worth running
Three situations where it genuinely earns its cost.
- Early design. You have a prototype and you want to know whether it is obviously weak before you spend on a full programme. A 1A failure is cheap information.
- Screening a change. A board grade swap, a new supplier, a different closure. 1A tells you quickly whether the change made things worse.
- Incoming quality. Repeatable, comparable and quick enough to run more than once, which suits checking that what arrives matches what was approved.
What it is not is a qualification test. If a customer, a retailer or a carrier has named a procedure, run the one they named. A 1A report is real accredited data, but it answers a different question from the one a procurement team is asking.
What the test involves
- Preconditioning at lab ambient.
- Vibration, using fixed-displacement motion, with the duration derived from the frequency rather than set as a flat clock value.
- Shock, by drop, incline impact or horizontal impact, at a severity set by the packed weight.
That is the whole sequence, and its shortness is the feature. There is no compression test and no atmospheric conditioning in 1A, which is exactly what separates it from 2A and from the 3-series. Adding conditioning is the single change that moves a test from screening into partial simulation.
One routing rule to check first: if the product is heavier than a set threshold and travels on a visible skid or pallet, the standard sends you to a different procedure. We check that before quoting rather than after.
How 1A compares to 2A and 3A
- 1A is screening. Strength only, no simulated hazard, no conditioning.
- 2A is partial simulation. The same base with conditioning required on top.
- 3A is general simulation. A full reproduction of the parcel environment, and what most specifications actually call for.
A 1A pass does not satisfy a 3A requirement, even at the same weight. They sit on a severity ladder and buyers who name a step generally know why. If you are unsure what your customer has asked for, send us the wording rather than guessing at it.
What we need from you to quote it
- The packed weight and the three outside dimensions.
- Whether it ships on a skid or pallet.
- What the report is for: internal design work, incoming quality, or a customer requirement.
That third one matters most. If the answer is a customer requirement, 1A is very often not the right test, and we would rather tell you that on the phone than after the report is issued.
Related package testing
1A is the entry point to the wider ISTA series, below 2A and 3A. For freight rather than parcel, see 3B. For a customer-defined distribution cycle, see ASTM D4169. Everything sits under package testing services.
Your Partner for ISTA 1A
An ISTA Certified Lab
Audited by ISTA, with the ISTA 1 Series on our A2LA ISO 17025 scope.
Quick Turnaround
A short sequence on a single specimen, so screening results come back fast.
We Will Tell You If It Is Not Enough
If a customer specified a simulation test, screening will not close it out, and we will say so.
Frequently Asked Questions
Common questions about ISTA 1A testing.
A non-simulation integrity test for individually packaged products. It challenges packaging strength with vibration and shock and reports whether it held. It does not attempt to reproduce a distribution environment, and the standard says so directly.
1A is screening, 3A is general simulation. 1A challenges strength with no simulated hazard and no conditioning. 3A reproduces the parcel distribution environment, including a hazard impact.
A 1A pass does not satisfy a 3A requirement, even at the same weight.
Usually not, if the customer named a procedure. Retailers, carriers and industrial buyers tend to specify a 3-series test, and a screening report answers a different question from the one their procurement team is asking.
Where the choice is yours, 1A is a legitimate and cheap way to get accredited evidence. Send us the requirement wording and we will tell you which it is.
No. 1A covers vibration and shock only. Other procedures in the 1-series do add a compression conditioning step, and the 3-series handles stacking load differently again, so if compression matters to you tell us and we will point you at the right one.