ASTM F1980 Accelerated Aging for Sterile Barrier Systems
Put a shelf life on a sterile barrier system without waiting years for it. ASTM F1980 accelerated aging, run in our own accredited temperature and humidity chambers in Aurora, Ontario.
- Evidence for an Expiration Date Claim: The reason the standard exists, and the reason medical device files need it.
- Accredited Chambers: ASTM F1980 sits on our A2LA ISO/IEC 17025 scope on the temperature and humidity line.
- We Scope Both Halves: Aging is chamber time. What proves the result is the testing afterwards, and we quote them together.
- Your Storage Assumption Sets the Duration: Send the shelf life you want and the ambient it will see, and we will size the programme.
Accredited package testing

ISO/IEC 17025
A2LA #5179.01

ISTA certified
Certified test laboratory
*Send the shelf life you need to claim, the storage temperature the product will see, and what the sterile barrier is made of. That is enough for us to size the programme and quote it.
What is ASTM F1980 accelerated aging?
F1980 is how a medical device manufacturer puts a shelf life on a sterile barrier system without waiting out the shelf life first.
The principle is chemical. Degradation reactions run faster at higher temperatures, so a package held in a warm chamber for weeks can model years of storage at room temperature. The standard sets out how to build that model honestly: which temperature to age at, what ambient to compare it against, and how far you are entitled to push before the acceleration stops being a fair representation.
Worth being precise about what it is. F1980 is a Standard Guide, not a test method. It produces no pass or fail of its own. What it produces is a protocol, and the standard is explicit that information obtained through it may serve as evidence for an expiration date claim. That sentence is why it appears in device submissions.
ASTM F1980 is on Megalab’s A2LA ISO/IEC 17025 scope, on the temperature and humidity line, and the chambers are in our own building in Aurora.
What decides how long your programme runs
Three inputs, and between them they set the whole schedule and most of the cost.
- The shelf life you want to claim. The longer the claim, the longer the chamber time.
- The ambient temperature you are aging against. This is the storage condition the product will really see. Choosing a higher ambient produces a longer and more conservative programme, and where a product is labelled with a storage range the standard recommends working from the top of that range rather than the middle.
- What the sterile barrier is made of. The aging temperature has to stay below any physical transition in the materials. Push past one and you are no longer accelerating the same degradation, you are causing a different one.
The standard gives the equation that ties those together. What it deliberately does not give is the aging factor for your particular material, and it says so: determining that factor sits outside the guide. Where there is no supporting data, the standard requires a conservative choice, which is the right instinct anyway when the output is going into a regulatory file.
What accelerated aging does not do
Four limits, all stated in the standard, and each one is somewhere a programme can go wrong.
- It does not replace real-time aging. F1980 covers the accelerated half only. Real-time studies still run in parallel, and accelerated results stay provisional until real time confirms them.
- It does not establish label storage conditions. Shelf life yes. The storage conditions printed on the label are a different question and the standard says its data must not be used for them.
- Aging and performance testing are separate things. Aging asks whether the material degraded over modelled time. Performance asks whether the package survives being handled and shipped. Customers routinely expect one programme to answer both. It does not, and that is worth settling before a purchase order is written.
- It does not set your acceptance criteria. Those have to exist before aging begins, and the standard is explicit that establishing them is outside its scope.
The testing that happens after the aging
Chamber time on its own proves nothing. What proves something is what you measure on the aged samples afterwards, and that is where most of the value of the programme sits.
The usual evaluations are seal strength and package integrity: whether the seals still hold, and whether the barrier still keeps the contents sterile. The standard points at a companion guide for choosing between the available methods, and the right choice depends on whether your barrier is a pouch, a tray with a lidding film, or a rigid container.
Megalab runs the aging in house under our accredited temperature and humidity capability, and manages the integrity methods within the same programme. You get one quote, one point of contact and accredited data on both halves. Tell us what your customer or your notified body expects to see and we will scope the whole loop rather than the chamber time alone.
What we need from you to quote it
Six things, and the first three do most of the work:
- The shelf life you need to claim.
- The storage temperature or labelled storage range.
- What the sterile barrier system is made of.
- Whether real-time aging is running alongside it, which it should be.
- Which post-aging tests are required, and who is asking for them.
- Your acceptance criteria, if they are already set.
From that we size the programme, confirm the chamber schedule, scope the post-aging testing and quote the whole thing. If your acceptance criteria are not settled yet, say so and we will flag what needs deciding before anything goes in a chamber.
Related testing
Accelerated aging sits next to the conditioning practice that governs atmospheres generally, ASTM D4332, which F1980 points at for environmental challenging.
Where a package also has to survive the trip rather than only the shelf, that is distribution testing: ISTA procedures for a fixed published sequence, or ASTM D4169 where the route needs describing from scratch. Everything sits under package testing services, and the chamber capability behind this page is the same one used for environmental testing.
Your Partner for Shelf Life
Accredited to ISO 17025
ASTM F1980 is on our A2LA scope, so the aging data is accredited.
Chambers In House
Aging runs in our own chambers in Aurora, so the schedule is ours to control.
Both Halves in One Quote
Aging and the post-aging integrity testing, scoped together.
Frequently Asked Questions
Common questions about ASTM F1980 accelerated aging.
Holding a package at a raised temperature to model the effect of years of normal storage in a much shorter time. Degradation reactions run faster when it is warmer, so weeks in a chamber can stand in for years on a shelf.
For sterile barrier systems and medical devices the standard covering it is ASTM F1980, and the output is evidence supporting an expiration date claim.
It depends on the shelf life you are claiming and the ambient temperature you are aging against, and those two are yours to set rather than ours.
A longer claim means more chamber time. A more conservative ambient assumption also means more chamber time, which is the trade worth understanding early: a cautious assumption is easier to defend and slower to deliver. Send us the claim and the storage condition and we will give you a real duration rather than a range.
No. F1980 covers the accelerated half only, and says so directly.
Real-time studies run alongside, and the accelerated result stays provisional until real time confirms it. That is the normal pattern: accelerated data supports the claim now, real-time data validates it as it accrues. Anyone telling you the accelerated study alone closes the question is skipping a step the standard does not skip.
Seal strength and package integrity, usually. The aging itself proves nothing until you measure whether the seals still hold and the barrier still keeps the contents sterile.
Which methods apply depends on the format of the barrier, whether that is a pouch, a tray with a lidding film or a rigid container. We run the aging here under accreditation and place the integrity methods with ISO 17025 accredited partners, quoted together so you deal with one lab.
No, and the standard separates them explicitly. Aging asks whether the materials degrade over modelled time on a shelf. Distribution testing asks whether the package survives being dropped, vibrated and stacked on its way to the customer.
A sterile barrier usually needs both, and they are two programmes rather than one. If you need the shipping side as well, that is ISTA or ASTM D4169, and we will scope them alongside each other.