Package Testing for a Damage-Free Delivery
From ISTA and ASTM to specific requirements for Amazon and Sam’s Club, we ensure your packaging protects your product and satisfies your partners.
- Prevent Costly Shipping Damage: Drastically reduce product returns and protect your brand reputation.
- Reduce Packaging Costs: Use precise data to eliminate over-packaging and save on materials.
- Meet Retailer & Carrier Requirements: Ensure compliance with mandatory protocols from Amazon, Sam’s Club, and FedEx.
- ISTA & ASTM Compliance Testing: Verify your packaging's integrity against globally recognized test methods.
Accredited package testing

ISO/IEC 17025
A2LA #5179.01

ISTA certified
Certified test laboratory
*Receive a detailed quote and project timeline, typically within one business day.
What a package testing lab does, and where to get it done in Canada
A package testing lab puts your packed product through the drops, vibration, compression and atmospheric conditions of a real distribution route, under controlled conditions, and reports whether the packaging held. Megalab runs that work in Aurora, Ontario, under ISO/IEC 17025 accreditation from A2LA. The accredited methods include ASTM D4169, D999, D5276, D5487 and D7386, the ISTA 1, 2, 3, 4, 6 and 7D series, and Transport Canada TP 14850.
For most products the requirement comes from your buyer rather than from a regulator. Amazon, FedEx and Sam’s Club each publish a protocol their vendors have to pass, and retail and industrial customers routinely make an ISTA or D4169 report a condition of the purchase order. When packaging fails in transit the cost is rarely just the broken unit. It is the return, the replacement shipment, and a buyer who now wants the test report you did not have.
A Full Suite of Package Testing & Certification Services
The global standard for simulating transport hazards. We perform the full range of ISTA tests to ensure your packaged-product can withstand the shocks, vibrations, and compressions of a typical shipping route.
Evaluate your packaging against the rigorous performance standards set by ASTM International. We conduct tests like ASTM D4169 to provide a standardized evaluation of your container's shipping performance.
Meet the mandatory requirements of the Amazon Packaging Support and Supplier Network (APASS). We help you pass Frustration-Free Packaging (FFP), Ships-in-Own-Container (SIOC), and other Amazon-specific tests.
Meet the requirements of the FedEx Packaging Services Lab. We test to ISTA 6-FedEx Procedures A through F on our own drop and vibration rigs, and the report comes back under our A2LA accreditation.
Not sure which one your customer is asking for? Our guide to choosing between ISTA and ASTM D4169 sets out how the two differ and which a given buyer usually means.
Packages that fail in transit usually fail on the shake table first, so vibration and shock testing is worth reading alongside this.
Protect Your Product. Satisfy Your Partners.
Prevent Costly Shipping Damage
Our accredited testing validates your packaging's durability, preventing costly returns and protecting your brand reputation.
Meet Critical Partner Requirements
We ensure you have the certified test reports needed to satisfy the mandatory requirements of Amazon, Sam’s Club, and FedEx.
Test with an Accredited Lab
Test in our globally recognized ISTA & ISO 17025 Accredited Lab to get accurate, repeatable, and defensible test data.
Frequently Asked Questions
Common questions about distribution testing, ISTA procedures and ASTM D4169.
Packaging work splits into two questions. Does the package survive the trip, and does it stay sealed. Distribution testing answers the first, and that is what the ISTA and ASTM D4169 families cover: conditioning, drops, vibration and a compression or top load step, run as a sequence that stands in for a real shipping lane. Integrity testing answers the second, and it belongs mostly to sterile and medical packaging.
Inside distribution testing the shipping channel picks the procedure. Parcel, less-than-truckload and full truckload each have their own, and the weight of the packed unit decides which variant of it applies. Where a retailer or a carrier is involved, they usually publish a program of their own rather than pointing at a generic one.
Megalab runs the distribution side in our own lab in Aurora, Ontario, under A2LA ISO/IEC 17025 accreditation. Depending on who is asking, start with ISTA, ASTM D4169 or the Amazon programs.
The phrase mixes two separate things, and untangling it saves real time.
ISTA certifies laboratories. It does not certify packages, and it does not certify the companies shipping them. A lab applies, gets audited, and holds the certification. Your package does not become certified by passing; it gets a report against the procedure that was run. So a customer asking for something “ISTA 3A certified” almost always needs a report from an ISTA certified lab showing the package passed 3A.
The number and the letter are the procedure, not a grade. The number is the series and the letter is the variant inside it, so 3A is the parcel procedure in the general simulation series. There is no procedure called 6A. The 6 series is the retailer and carrier programs, and those are named after the retailer instead of lettered, so “6A” in a specification usually means one of them and is worth confirming before anyone quotes it.
Megalab is an ISTA certified laboratory, audited by ISTA.
They solve the same problem from opposite ends.
ISTA hands you a finished procedure. Find the one matching your channel and your weight, and the sequence, the levels and the pass criteria are already set. D4169 hands you a framework instead: you choose a distribution cycle describing the route, choose an assurance level, and the standard assembles the schedule from those two choices. That makes D4169 the better fit for an unusual route, and ISTA the faster answer for an ordinary one.
Usually the choice has already been made for you. A retailer or a purchase order names ISTA. An engineering specification or a medical device file more often names D4169, because it can be written around a route no published procedure describes.
If nothing has been named, the shipping channel decides it. Send the packed weight, the outside dimensions and how the product travels, and we will tell you which one applies before you commit to anything.
Yes, and it catches people out. Those are the ISTA 6 series, the retailer and carrier programs, written by the retailer rather than by ISTA’s general committees. They reuse the same drop and vibration building blocks as the 3 series, then add their own package classification, their own acceptance criteria and often their own paperwork.
Amazon has the most moving parts, because which of its programs applies depends on how the item ships rather than on what it is. Amazon package testing covers those. Other retailers publish requirements of their own again, Costco among them.
Our accreditation covers the 6 series, including the Amazon, Sam’s Club and FedEx programs. If a program has been named at you and you are not sure which variant applies, send the details and we will confirm it before quoting.
Yes, and across the range rather than a handful of procedures. Our ISO/IEC 17025 accreditation from A2LA covers the ISTA 1, 2, 3, 4 and 6 series and 7D, together with ASTM D4169, D5276, D5487, D7386, D999 and TP 14850. We are also an ISTA certified laboratory, audited by ISTA.
What that changes is what the report is worth. Accredited data is something your customer’s quality group can accept without a second conversation about who ran it and how.
The certificates are listed on our accreditations page.
Yes. It is worth knowing how it differs from everything above.
Integrity asks whether the package leaks or whether a seal has failed. Distribution asks whether it survives the trip. The two arrive together on medical and sterile barrier projects, where ISO 11607-1 sits over the top as the master standard and calls out the individual methods underneath it.
We run the distribution half here under accreditation and manage the integrity methods within the same programme, so it stays one quote and one point of contact. Tell us which standard your customer named and we will scope both halves.