Radiated Emissions Testing
Accredited radiated emissions testing in our 10 m semi-anechoic chamber, for FCC, ISED and CE compliance.
- A Full 10 m Chamber: Equipment up to 4 m wide and 3 m tall is measured at 10 m, the distance FCC Class A limits use and one CISPR 32 allows.
- Standards for North America and Europe: We test to FCC Part 15B, ICES-003 and CISPR 32, and to CISPR 25 for automotive components.
- One Campaign, Two Countries: ICES-003 accepts the same ANSI C63.4 method as FCC Part 15B, so one test campaign produces the data for both.
- Engineers Who Find the Source: When a frequency fails, our engineers help trace it to a cable, a clock or a seam and retest.
Accredited EMC testing

ISO/IEC 17025
A2LA #5179.02

FCC recognized
Part 15/18/22 · wireless

ISED recognized
CAB CA0102
* Tell us your requirements for a detailed quote and project timeline. We’ll respond within 24 hours.
What is radiated emissions testing?
Radiated emissions testing measures the unintentional radio frequency energy a product gives off through the air, from its circuit boards, its enclosure and above all its cables. Standards such as FCC Part 15B, ICES-003 and CISPR 32 set the limits, and almost every electronic product sold in the US, Canada or Europe has to pass before it goes on sale.
Every digital circuit switches, and every switching edge produces energy at the clock frequency and its harmonics. Cables attached to the product act as antennas for that energy. Left unchecked, it interferes with nearby radio, cellular and GPS receivers, so regulators limit it. It is sometimes called a radiation emission test.
Limits come in two classes. Class B applies to products used in homes and is stricter; Class A applies to commercial and industrial equipment. The product standard and the market decide which one you meet.
Which products need radiated emissions testing?
Nearly anything with electronics inside. Computers and consumer electronics fall under FCC Part 15B, ICES-003 and CISPR 32; industrial machinery, lab instruments and medical devices usually reach CISPR 11 through their product standard.
Products with a radio transmitter need radiated emissions testing for their digital circuitry too. If the radio is a certified module used unchanged within its grant, the host usually needs FCC Part 15B and ICES-003 testing for its own digital circuitry, plus a short set of radio checks with the module transmitting inside your product, rather than a full radio retest. Testing of the transmitter itself, including radiated spurious emissions, is covered on our wireless testing pages.
How radiated emissions testing works
Test setup in our 10 m semi-anechoic chamber
The product sits on a turntable, on a non-conductive table if it is table-top equipment or on low supports if it stands on the floor. A receiving antenna on a mast faces it across the chamber at the distance the standard specifies. The chamber’s shielded walls keep outside signals out, the absorber lining the walls and ceiling stops reflections, and the metal floor acts as the reference ground plane.
Cables are laid out as the standard describes, because the cables usually radiate more than the product itself.
Finding the worst case
- Scope the test. We confirm the standard, the class, the frequency range and the operating modes with you.
- Preview scan. A fast scan across the full frequency range shows where the product’s emissions sit.
- Maximize. For each significant peak we rotate the product through 360 degrees and raise and lower the antenna, in both horizontal and vertical polarization.
- Vary what matters. We try cable positions and operating modes and keep whichever is loudest.
- Final measurement. Each peak is measured with the detectors the standard specifies and compared with the limit.
- Report. You receive an accredited test report showing every measured frequency and its margin to the limit.
Radiated emissions tests we perform
Below and above 1 GHz
Below 1 GHz, most standards measure with a quasi-peak detector. Above 1 GHz the method changes to peak and average detectors, and the upper frequency depends on the highest clock or frequency used inside your product, so a fast processor pushes the scan well into the GHz range.
Vehicle and component emissions to CISPR 25 and CISPR 12
Automotive electronic modules are tested to CISPR 25 to protect the vehicle’s own receivers, and CISPR 12 covers emissions from vehicles, boats and engine-driven machines. Both sit alongside ISO 11452-2 and ISO 11452-4 immunity testing for automotive components.
On-site CISPR 11 testing for installed equipment
Our accreditation includes field testing to CISPR 11 and EN 55011, so a machine that cannot come to the chamber can be measured where it is installed. On site, CISPR 11 assesses radiated emissions rather than conducted ones. We run an ambient scan with the equipment switched off first, then measure its emissions in operation.
Military radiated emissions
We also support MIL-STD-461 radiated emissions, such as RE102, delivered through our in-house partner lab.
Radiated emissions standards we test to
Some of the standards we test to include:
| Standard | What it covers | Typical products |
|---|---|---|
| FCC Part 15 Subpart B (ANSI C63.4) | US unintentional radiators | IT equipment, consumer electronics, digital devices |
| FCC Part 18 (MP-5) | US consumer ISM equipment | Induction cooking, RF heating and lighting equipment |
| ICES-003 | Canada, IT and digital apparatus | Computers, networking gear, electronic products |
| ICES-001, ICES-002, ICES-005 | Canada, ISM equipment, vehicles, boats and engine or battery powered devices, lighting | Industrial RF equipment, engine-driven machines, luminaires |
| CISPR 32 / EN 55032 | Multimedia equipment | Computers, displays, audio and video equipment |
| CISPR 11 / EN 55011 | Industrial, scientific and medical equipment | Machinery, lab instruments, medical devices |
| CISPR 15 / EN 55015 | Lighting equipment | Luminaires, LED drivers, smart lighting |
| CISPR 25 / EN 55025 | Vehicle components | ECUs, infotainment, chargers, motor controllers |
| CISPR 12 | Vehicles, boats and engine-driven devices | Off-road machines, utility vehicles |
| IEC 61326-1 | Measurement, control and lab equipment | Test instruments, process controllers |
| IEC 60601-1-2 | Medical electrical equipment | Patient monitors, diagnostic and therapy devices |
| IEC 61000-6-3 / IEC 61000-6-4 | Generic emissions, residential and industrial | Products with no dedicated product standard |
| EN 50121 | Railway applications | Rolling stock and trackside electronics |
| VCCI, KN 32 (KS C 9832), AS/NZS CISPR 32 | Japan, Korea, Australia and New Zealand | ITE and multimedia equipment for those markets |
Our testing is ISO/IEC 17025 accredited by A2LA under certificate 5179.02; see our accreditations.
Technical specifications
- 10 m semi-anechoic chamber, plus a second 3 m semi-anechoic chamber
- Radiated measurements from 9 kHz to 40 GHz, including FCC Part 15B and Part 18
- Measurement distances: 10 m and 3 m below 1 GHz, 3 m from 1 GHz to 40 GHz
- 4 m turntable rated to 10,000 lb; 3 m x 3 m chamber door; equipment up to 4 m wide and 3 m tall
- Single-phase, three-phase and DC power to the equipment, up to 600 V and 100 A
- Loop (9 kHz to 30 MHz), BiLog (30 MHz to 1 GHz) and horn (1 GHz to 40 GHz) antennas; CISPR 16-1-1 compliant receivers
- Chamber validated for normalized site attenuation (30 MHz to 1 GHz) and site VSWR (1 GHz to 18 GHz) to CISPR 16-1-4 and ANSI C63.4
- Field testing to CISPR 11 / EN 55011 at your site
Why products fail radiated emissions
Most failures come from a short list of sources:
- Cables. Common-mode current on a USB, Ethernet or power cable turns it into an efficient antenna. This is one of the most frequent causes.
- Clock harmonics. Fast edges on processors, memory and displays put energy at multiples of the clock frequency.
- Enclosure seams and openings. Slots, vents and poorly bonded panels let energy escape from a metal enclosure.
- Board layout. Broken return paths and split ground planes raise the loop area of fast signals.
An EMC pre-scan finds these before the formal run, and during testing our engineers help trace a failing frequency to its source so the fix can be checked in the same program.
Radiated emissions vs radiated immunity
Radiated emissions testing asks whether your product disturbs the radio spectrum. Radiated immunity testing asks the opposite: whether your product keeps working when it is exposed to a strong radio field, to IEC 61000-4-3. Most CE EMC product standards require both, and we test both in the same lab. See radiated immunity testing.
Why test with Megalab
A 10 m chamber. Racks and floor-standing machines up to 4 m wide and 3 m tall are measured at 10 m.
Accredited and recognized. ISO/IEC 17025 accredited by A2LA under certificate 5179.02, FCC recognized, and ISED recognized under CAB CA0102.
North America and Europe in one campaign. ICES-003 accepts the ANSI C63.4 method FCC Part 15B uses, and CISPR 32 can run in the same visit.
The whole compliance package in one lab. EMC, environmental and product safety testing all run at our lab in Aurora, Ontario.
What we need to quote you
- Product type, a short description and photos
- Power: AC mains, DC or battery; voltage, phase and rated current
- Dimensions and weight, and whether it is table-top or floor-standing
- The highest clock or internal frequency in the product
- Operating modes, and any radio modules with their grant numbers
- Target markets and the standard, if you know it, including Class A or Class B
- Cables and ports the product uses in service, with lengths
- Samples available, and whether you want a pre-scan first
Send us the details and we will confirm the requirement and quote it.
Radiated emissions testing FAQ
A radiated emission test measures the radio frequency energy a product gives off through the air. The product runs on a turntable in a chamber while an antenna scans for emissions, which are compared with the limits in standards such as FCC Part 15B, ICES-003 and CISPR 32.
The measurement usually starts at 30 MHz, where conducted emissions testing hands over. The upper limit depends on the highest frequency generated or used inside the product, so a product with fast clocks is measured well into the GHz range.
Standards set their limits at a stated measurement distance, and the limit changes with that distance. A 10 m chamber lets large equipment be measured at the 10 m distance used for FCC Class A limits and allowed by CISPR 32.
Radiated emissions travel through the air and are measured with an antenna. Conducted emissions travel along the cables and are measured at the power and network ports. Mains-powered products usually need both; see conducted emissions testing.
Bring the cables and support equipment the product uses in service, and a way to run each operating mode. A pre-scan shows your margins while changes are still cheap.
The report shows which frequencies failed and by how much. Our engineers help trace the source, and the product is retested once the fix is in.
Yes, in most cases. ICES-003 accepts the ANSI C63.4 method that FCC Part 15B uses, so one test campaign produces the data for both, reported against each rule.
Ready to test? Send us your product details and we will confirm the radiated emissions requirement and quote it. Request a Radiated Emissions Quote.
Your Partner for EMC Compliance
Room for Large Equipment
Our 10 m semi-anechoic chamber takes equipment up to 4 m wide.
Engineers Who Find the Source
When a frequency fails, we help trace it and retest.
Accredited EMC Testing
ISO/IEC 17025 accredited by A2LA, certificate 5179.02. See our accreditations.