Corrosion Testing for Long-Term Product Durability


Ensure your products can withstand the harshest real-world environments. Our accredited lab provides a full suite of corrosion testing services, including ASTM B117 salt spray, to validate the durability of your materials and coatings, prevent premature failures, and protect your brand.

  • Prevent Premature Failures: Identify and correct material and coating weaknesses before they lead to costly warranty claims and field failures.
  • Validate Material Performance: Get the defensible, accredited data you need to make informed decisions about your coatings, finishes, and base materials.
  • Meet Demanding Industry Standards: Prove your product's resilience for use in marine, automotive, aerospace, and other corrosive environments.
  • Test with an ISO Accredited Partner: Test in calibrated salt spray chambers, with engineers who run these methods every week, for precise and repeatable results.
>> Learn more about our services

Trusted by industry leaders

What is salt spray testing?

Salt spray testing, also called salt fog or salt mist, holds a product in a heated chamber filled with a fine mist of salt solution to accelerate corrosion that would otherwise take months or years outdoors. The reference method is ASTM B117, and the equivalents are IEC 60068-2-11 Test Ka and MIL-STD-810 Method 509. Megalab runs salt fog testing at a 5 % salt solution, accredited to ISO/IEC 17025 by A2LA under certificate 5179.01.

What salt spray actually tells you, and what it does not

Salt spray is a comparative test, not a predictive one. It will tell you that coating A outlasts coating B, that a fastener choice is wrong, or that a seam is where water gets in. It will not tell you how many years a product survives on a coastal site, and any supplier who converts exposure hours into years of service life is guessing.

That is why specifications express the requirement as a duration and an acceptance criterion rather than as a lifetime. The failures it surfaces are consistent: white rust on zinc, red rust through a coating, blistering and undercutting at a scribe, galvanic attack where two metals meet, and corrosion tracking into an enclosure through a gasket line.

Which corrosion tests do we run?

Neutral salt fog to ASTM B117, the most commonly specified corrosion test and the one most customer documents mean when they say salt spray.

Salt mist to the IEC methods. IEC 60068-2-11 Test Ka is continuous exposure. IEC 60068-2-52 Test Kb is cyclic, alternating salt exposure with controlled humidity, which is closer to real service for outdoor products and markedly more severe than the same nominal hours of continuous fog.

Sulphur dioxide exposure to ASTM G85, IEC 60068-2-42 and ISO 6988, for industrial atmospheres where the corrosive agent is not chloride. This is a separate accredited line on our certificate, not a variant of salt fog.

Component, connector and enclosure methods: MIL-STD-202 Method 101, MIL-STD-883 Methods 1009 and 1031, MIL-STD-1344 Section 1001, EIA-364-26 and RTCA DO-160 Section 14.

Enclosure programmes usually pair corrosion with an ingress rating, since a gasket that passes water may still corrode at the seam. See ingress protection testing and NEMA enclosure testing, where corrosion resistance is a Type requirement in its own right.

Which corrosion standards do we test to?

  • ASTM B117: neutral salt spray, the reference method.
  • IEC/EN 60068-2-11 Test Ka: salt mist, continuous.
  • IEC/EN 60068-2-52 Test Kb: salt mist, cyclic.
  • MIL-STD-810 Method 509: salt fog for military and rugged equipment.
  • MIL-STD-202 Method 101 and MIL-STD-883 Methods 1009 and 1031 for components and microcircuits.
  • MIL-STD-1344 Section 1001 and EIA-364-26 for connectors.
  • RTCA DO-160 Section 14 for airborne equipment.
  • IEC/EN 60950-22 for equipment installed outdoors.
  • ASTM G85: modified salt spray practices including the SO2 variants.
  • IEC/EN 60068-2-42 Test Kc and ISO 6988 for sulphur dioxide atmospheres.
  • IEC/EN 61300-2-28 for fibre optic interconnects.

Our scope also covers customer supplied and industry specifications built on these same technologies, so an internal procedure can be run and reported under the accreditation. Send us the document and we will confirm.

Accredited by A2LA to ISO/IEC 17025 under certificates 5179.01 and 5179.02. See our accreditations.

How long does salt spray testing take?

Your specification sets it. Salt spray requirements are written as an exposure duration with an acceptance criterion, and that duration is the single biggest driver of what the test costs, because the chamber is committed for the whole run. A short qualification and a long one are the same work per hour and very different bookings.

Tell us the hours your specification calls for, how many samples you have, and whether you need interim inspections during the exposure, and we will confirm the requirement and quote it. If your specification gives a criterion but no duration, that is a gap worth closing before anything is booked, and we will flag it.

What we need to quote your corrosion test

  • The standard and method, or your internal specification
  • The exposure duration and the acceptance criterion your specification defines
  • Sample dimensions, quantity, and the material and finish under test
  • Whether samples are scribed, and to what pattern
  • Whether you need interim inspections during the exposure, and who performs them
  • Mounting angle and orientation, which the standards specify and which changes the result
  • Whether the programme also needs ingress or NEMA enclosure testing

Send us the specification and we will confirm the requirement and quote it.

Frequently asked questions

A controlled exposure that accelerates corrosion so a product, coating or finish can be compared against an acceptance criterion in days rather than years. Salt spray is the most common form.

ASTM B117 is the reference method. IEC 60068-2-11 Test Ka and IEC 60068-2-52 Test Kb are the international equivalents, continuous and cyclic. MIL-STD-810 Method 509 covers military and rugged equipment, and RTCA DO-160 Section 14 covers airborne equipment. All of those are on our accredited scope.

ISO 9227, the ISO counterpart to ASTM B117. Send us your specification and we will confirm the right method and quote it.

Shorthand for a salt spray exposure lasting 72 hours, one of several durations a specification may call for. The number comes from your specification rather than from the standard, which defines how the test is run rather than for how long.

Usually, yes, at the same nominal hours. Cycling between salt exposure and controlled humidity lets the surface wet and dry repeatedly, which drives more realistic attack than a continuously saturated surface.

What our clients say

4.8
Neil Y. profile picture
Neil Y.
8 months ago
Working with MegaLab has been an outstanding experience from start to finish. Garry, Vik, Sreyas, and Alex are a fantastic team — knowledgeable, responsive, and genuinely easy to work with. Turnaround times have consistently been faster than expected, and the level of technical expertise they bring to every project gives us full confidence in the results. Communication is seamless, and it's clear they take the partnership seriously. If you're looking for a reliable, professional lab you can count on, MegaLab is the real deal — highly recommend!
Ada L. profile picture
Ada L.
2 years ago
Megalabs supported us extensively with testing as we prepared for the FDA submission of our first medical device. Their team is composed of some of the most dedicated and detail-oriented professionals I’ve had the pleasure of working with—especially Vik, Brooke, Sreyas, Solomon, Famous, and Marty. They generously gave us a tour of their facilities and were always willing to take calls and attend meetings, even across different time zones. I’m incredibly grateful for their support—they truly went above and beyond.
We had a fantastic experience working with Megalab on our IEC 60601 testing. Their technical knowledge and attention to detail were clear from day one, and they went above and beyond to keep us on track for our first medical device FDA submission.

The team was easy to communicate with, quick to respond, and truly committed to our success. Marty, Vic , Soliman, and even the accounting team provided us with white glove service. Not to mention that their facility is truly impressive!

We wouldn’t hesitate to work with them again, in fact we are looking forward to it!

Related Environmental Testing Services

Other Megalab Testing Services

Let's Start Your Project


Fill out the form below, and one of our lead engineers will contact you within 24 hours to discuss your project.

Contact Information

Address

150 Addison Hall Circle,
Aurora, ON, Canada, L4G 3X8

Phone

+1-905-752-1925

Email

info@megalabinc.com

Business Hours

Monday - Friday: 9:00 AM - 5:00 PM

We respond to all inquiries within one business day.

Certifications & Accreditations

> View all Accreditations

Request a Quote

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
(Optional, but helps us respond faster)

Ready to ensure your product meets global compliance standards?

Partner with Megalab for comprehensive testing solutions and expert guidance throughout your compliance journey.


Get Your Free QuoteOr Call Us Today: +1(905)-752-1925
About
A2LA accredited laboratory symbol

Megalab Group Inc. is an ISO 17025 A2LA Accredited Independent Compliance Testing Laboratory located in Aurora, ON, Canada.

>> Learn more about what we do

© 2026 Megalab Group Inc. All rights reserved
View our Privacy Policy + Terms of Service

Top

Privacy Preference Center

Request a Quote