IEC 62368-1 Safety Testing for Audio/Video & IT Equipment
Hazard-based safety testing for audio, video and ICT equipment, in our ISO/IEC 17025 accredited lab, including the legacy standards it replaced.
Why Manufacturers Choose Megalab:
- The Series and the Standards It Replaced: We test to IEC 62368-1 and the 62368 series, as well as IEC 60950-1 and IEC 60065.
- Built for the Transition: A legacy design and its 62368-1 successor can be assessed by the same engineers.
- We Classify Before You Commit: Send us the schematic and the enclosure and we will tell you which energy sources are in scope before you book anything.
- EMC and Safety In One Building: Emissions, immunity and the safety work all run in Aurora, Ontario, on one schedule.
Accredited product safety testing

ISO/IEC 17025
A2LA #5179.02
NRTL Marking
Certifier-matched testing
CE Marking
LVD, EMC & Machinery Directive testing
*A 15-minute introductory call to discuss your project. No obligation.
What does IEC 62368-1 actually cover?
IEC 62368-1 is the safety standard for audio, video, information and communication technology equipment. It replaced two older standards that used to split this territory between them: IEC 60950-1 for information technology equipment and IEC 60065 for audio and video equipment.
It is not a merger of the two. It works on a completely different principle, called hazard-based safety engineering. Instead of prescribing constructions that were known to be safe for a particular product type, 62368-1 asks you to find the energy sources inside your product, classify how dangerous each one is, decide who might come into contact with it, and then prove that something adequate stands between the two.
That change is why a design that passed 60950-1 comfortably can need real work to satisfy 62368-1, and why the first question we ask is about energy sources rather than about product category.
How is 62368-1 different from 60950-1 and 60065?
The older standards were prescriptive. They described constructions, clearances and materials that experience had shown to be safe for a defined class of product, and compliance largely meant matching your design to those descriptions.
62368-1 is hazard-based. It starts from the energy in the product rather than from the product’s category, which has three practical consequences worth knowing before you plan a program.
The first is that your product type matters less than what is inside it. A speaker, a server and a network switch are assessed by the same method.
The second is that you have to name your own energy sources and justify the classification. That is engineering work, and it is work the standard expects the manufacturer to bring rather than the laboratory to invent.
The third is that a safeguard has to be demonstrated, not merely present. Showing that an enclosure exists is not the same as showing it is an adequate safeguard against a class 3 energy source.
We test to both legacy standards, IEC 60950-1 and IEC 60065, as well as 62368-1. If you are moving an existing design across, the same engineers can look at the old report and the new requirement together.
Which energy sources does your product contain?
62368-1 sorts energy into five kinds, and grades each one into class 1, 2 or 3 by how much harm it could do. Class 1 is generally not painful or injurious, class 2 can be painful, class 3 can injure or start a fire. The class decides how many safeguards you need, so this classification is the spine of the whole assessment:
- ES1, ES2, ES3, electrical energy: graded by prospective touch voltage and touch current, under normal, abnormal and single-fault conditions.
- PS1, PS2, PS3, electrical power: graded by the power available to a circuit, which is what drives fire risk rather than shock risk.
- TS1, TS2, TS3, thermal energy: graded by touchable surface temperature, with limits that depend on the surface material.
- MS1, MS2, MS3, mechanical energy: moving parts, sharp edges, stored energy and anything that can cut, crush or strike.
- RS1, RS2, RS3, radiated energy: optical radiation, lasers and acoustic energy.
A class 2 source needs at least one safeguard between it and the person. A class 3 source needs a double or reinforced safeguard. Getting a classification wrong in either direction is expensive: too low and the safeguards fail assessment, too high and you have paid for construction the product never needed.
Who is expected to use it?
The second axis is the person. 62368-1 recognises three, and the same energy source can be acceptable for one and not another.
An ordinary person is a user or operator with no relevant training. An instructed person has been trained or is supervised by a skilled person, and can be expected to avoid unintentional contact. A skilled person has training or experience in the technology and is expected to recognise energy sources and protect themselves.
The consequences here are commercial as well as technical. A product sold to consumers and the same product sold into a data centre rack can face different requirements, and deciding which you are building for is a decision about your market as much as your design.
What does the testing involve?
Once the energy sources and the intended user are settled, the assessment covers:
- Electrical energy source classification and safeguard verification
- Power source classification and circuit power measurement
- Thermal energy hazards and touch temperature limits
- Fire enclosure and flame spread evaluation
- Mechanical and kinetic energy hazards, including moving and sharp parts
- Radiated energy assessment where optical, laser or acoustic sources are present
- Insulation coordination, creepage and clearance
- Power supply interfaces, external adapters and battery circuits
- Marking, instructions and instructional safeguards
Accredited testing. We test to UL, CSA, IEC and EN 62368-1 and the legacy standards in our ISO/IEC 17025 lab, accredited by A2LA. See our accreditations.
What do you need from me to quote it?
Six answers are usually enough for a firm number and a schedule:
- Rated input, and whether the product runs from the mains, an external adapter, a battery, or power over a data connection.
- Who uses it: ordinary, instructed or skilled person, and whether it is sold to consumers or into a controlled environment.
- Maximum available power in the accessible circuits, if you already know it.
- Enclosure material, and whether the enclosure is metal, plastic or a mix.
- Any moving parts, lasers, optical emitters or audio output, since each brings in its own energy class.
- Existing reports, including a CB certificate or a legacy 60950-1 or 60065 report if you are transitioning.
Which market versions can you test to?
62368-1 is adopted nationally with deviations, so the version matters. We test to the UL, CSA, IEC and EN versions, which covers North America and Europe from one program rather than sequential ones.
We also test to SI 62368 for Israel. If Israel is a target market, tell us at the enquiry so the program is scoped to the Israeli version.
Tell us every market you intend to sell into before the program is scoped. Testing the national versions together is considerably cheaper than discovering a deviation after a report is written.
Your Partner for IEC 62368
Both Generations Covered
IEC 62368-1 and the legacy standards it replaced, tested by the same engineers.
Classification First
We settle your energy sources and user type before anything is booked.
EMC in the Same Building
Emissions, immunity and safety run in Aurora on one schedule.
Frequently Asked Questions
Not automatically. The two standards reach their conclusions by different routes, so a 60950-1 report is useful evidence but not a substitute. Some of the underlying measurements transfer, and the construction is often already close, but the energy source classification and the safeguard justification are new work the older report does not contain. Send us the existing report with the enquiry and we will tell you how much of it still applies.
It means the standard asks about the energy in your product rather than the category your product sits in. You identify each energy source, classify it as class 1, 2 or 3, decide which type of person could contact it, and then demonstrate that the safeguards between them are adequate for that combination. The practical effect is that two very different-looking products can be assessed the same way, and that the manufacturer is expected to bring the classification rather than receive it.
They are closely related but not interchangeable. UL 62368-1 is the United States adoption, CSA C22.2 No. 62368-1 the Canadian, and EN 62368-1 the European, each adding national deviations to the IEC base document. Testing to the IEC version alone does not automatically satisfy a market that requires its national version, so name your target markets before the program is scoped. We test to all four.
The standard puts that work with the manufacturer, because it depends on design intent that only you hold. In practice most customers arrive with a partial view and we work through it together on the introductory call, which is usually enough to scope the program accurately. What we will not do is guess at a classification and quote around the guess, because an energy source found late is the most common reason a safety program overruns.
It depends on how many energy sources are in scope, how many models and configurations you need covered, whether radiated or mechanical sources bring in additional assessment, and whether the product passes first time. The schedule is set when we quote, and we give you a date rather than a range. The fastest route to an accurate one is to send the six items listed above under what we need to quote it.
*A 15-minute call to assess your project needs. No obligation.









